Med Phys ; 49(9): 5819-5829, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35838056

RESUMO

BACKGROUND: Hybrid imaging (e.g., positron emission tomography [PET]/computed tomography [CT], PET/magnetic resonance imaging [MRI]) helps one to visualize and quantify morphological and physiological tumor characteristics in a single study. The noninvasive characterization of tumor heterogeneity is essential for grading, treatment planning, and following-up oncological patients. However, conventional (CONV) image-based parameters, such as tumor diameter, tumor volume, and radiotracer activity uptake, are insufficient to describe tumor heterogeneities. Here, radiomics shows promise for a better characterization of tumors. Nevertheless, the validation of such methods demands imaging objects capable of reflecting heterogeneities in multi-modality imaging. We propose a phantom to simulate tumor heterogeneity repeatably in PET, CT, and MRI. METHODS: The phantom consists of three 50-ml plastic tubes filled partially with acrylic spheres of S1: 1.6 mm, S2: 50%(1.6 mm)/50%(6.3 mm), or S3: 6.3-mm diameter. The spheres were fixed to the bottom of each tube by a plastic grid, yielding one sphere free homogeneous region and one heterogeneous (S1, S2, or S3) region per tube. A 3-tube phantom and its replica were filled with a fluorodeoxyglucose (18F) solution for test-retest measurements in a PET/CT Siemens TPTV and a PET/MR Siemens Biograph mMR system. A number of 42 radiomic features (10 first order and 32 texture features) were calculated for each phantom region and imaging modality. Radiomic features stability was evaluated through coefficients of variation (COV) across phantoms and scans for PET, CT, and MRI. Further, the Wilcoxon test was used to assess the capability of stable features to discriminate the simulated phantom regions. RESULTS: The different patterns (S1-S3) did present visible heterogeneity in all imaging modalities. However, only for CT and MRI, a clear visual difference was present between the different patterns. Across all phantom regions in PET, CT, and MR images, 10, 16, and 21 features out of 42 evaluated features in total had a COV of 10% or less. In particular, CONV, histogram, and gray-level run length matrix features showed high repeatability for all the phantom regions and imaging modalities. Several of repeatable texture features allowed the image-based discrimination of the different phantom regions (p < 0.05). However, depending on the feature, different pattern discrimination capabilities were found for the different imaging modalities. CONCLUSION: The proposed phantom appears suitable for simulating heterogeneities in PET, CT, and MRI. We demonstrate that it is possible to select radiomic features for the readout of the phantom. Most of these features had been shown to be relevant in previous clinical studies.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Plásticos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons
2.
Z Med Phys ; 32(4): 466-476, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35597743

RESUMO

The choice of materials challenges the development of Magnetic Resonance Imaging (MRI) phantoms and, to date, is mainly limited to water-filled compartments or gel-based components. Recently, solid materials have been introduced through additive manufacturing (AM) to mimic complex geometrical structures. Nonetheless, no such manufactured solid materials are available with controllable MRI contrast to mimic organ substructures or lesion heterogeneities. Here, we present a novel AM design that allows MRI contrast manipulation by varying the partial volume contribution to a ROI/voxel of MRI-visible material within an imaging object. Two sets of 11 cubes and three replicates of a spherical tumour model were designed and printed using AM. Most samples presented varying MRI-contrast in standard MRI sequences, based mainly on spin density and partial volume signal variation. A smooth and continuous MRI-contrast gradient could be generated in a single-compartment tumour model. This concept supports the development of more complex MRI phantoms that mimic the appearance of heterogeneous tumour tissues.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Humanos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Impressão Tridimensional
3.
Sci Rep ; 11(1): 8838, 2021 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-33893323

RESUMO

A prototype of a navigation system to fuse two image modalities is presented. The standard inter-modality registration is replaced with a tracker-based image registration of calibrated imaging devices. Intra-procedure transrectal US (TRUS) images were merged with pre-procedure magnetic resonance (MR) images for prostate biopsy. The registration between MR and TRUS images was performed by an additional abdominal 3D-US (ab-3D-US), which enables replacing the inter-modal MR/TRUS registration by an intra-modal ab-3D-US/3D-TRUS registration. Calibration procedures were carried out using an optical tracking system (OTS) for the pre-procedure image fusion of the ab-3D-US with the MR. Inter-modal ab-3D-US/MR image fusion was evaluated using a multi-cone phantom for the target registration error (TRE) and a prostate phantom for the Dice score and the Hausdorff distance of lesions . Finally, the pre-procedure ab- 3D-US was registered with the TRUS images and the errors for the transformation from the MR to the TRUS were determined. The TRE of the ab-3D-US/MR image registration was 1.81 mm. The Dice-score and the Hausdorff distance for ab-3D-US and MR were found to be 0.67 and 3.19 mm. The Dice score and the Hausdorff distance for TRUS and MR were 0.67 and 3.18 mm. The hybrid navigation system showed sufficient accuracy for fusion guided biopsy procedures with prostate phantoms. The system might provide intra-procedure fusion for most US-guided biopsy and ablation interventions.

4.
EJNMMI Phys ; 8(1): 18, 2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33599876

RESUMO

BACKGROUND: PET/MRI phantom studies are challenged by the need of phantom-specific attenuation templates to account for attenuation properties of the phantom material. We present a PET/MRI phantom built from MRI-visible material for which attenuation correction (AC) can be performed using the standard MRI-based AC. METHODS: A water-fillable phantom was 3D-printed with a commercially available MRI-visible polymer. The phantom had a cylindrical shape and the fillable compartment consisted of a homogeneous region and a region containing solid rods of different diameters. The phantom was filled with a solution of water and [18F]FDG. A 30 min PET/MRI acquisition including the standard Dixon-based MR-AC method was performed. In addition, a CT scan of the phantom was acquired on a PET/CT system. From the Dixon in-phase, opposed-phase and fat images, a phantom-specific AC map (Phantom MR-AC) was produced by separating the phantom material from the water compartment using a thresholding-based method and assigning fixed attenuation coefficients to the individual compartments. The PET data was reconstructed using the Phantom MR-AC, the original Dixon MR-AC, and an MR-AC just containing the water compartment (NoWall-AC) to estimate the error of ignoring the phantom walls. CT-based AC was employed as the reference standard. Average %-differences in measured activity between the CT corrected PET and the PET corrected with the other AC methods were calculated. RESULTS: The phantom housing and the liquid compartment were both visible and distinguishable from each other in the Dixon images and allowed the segmentation of a phantom-specific MR-based AC. Compared to the CT-AC PET, average differences in measured activity in the whole water compartment in the phantom of -0.3%, 9.4%, and -24.1% were found for Dixon phantom MR-AC, MR-AC, and NoWall-AC based PET, respectively. Average differences near the phantom wall in the homogeneous region were -0.3%, 6.6%, and -34.3%, respectively. Around the rods, activity differed from the CT-AC PET by 0.7%, 8.9%, and -45.5%, respectively. CONCLUSION: The presented phantom material is visible using standard MR sequences, and thus, supports the use of standard, phantom-independent MR measurements for MR-AC in PET/MRI phantom studies.

5.
Med Phys ; 47(4): 2023-2037, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31981214

RESUMO

BACKGROUND: In oncology, lesion characterization is essential for tumor grading, treatment planning, and follow-up of cancer patients. Hybrid imaging systems, such as Single Photon Emission Computed Tomography (SPECT)/CT, Positron Emission Tomography (PET)/CT, or PET/magnetic resonance imaging (MRI), play an essential role for the noninvasive quantification of tumor characteristics. However, most of the existing approaches are challenged by intra- and intertumor heterogeneity. Novel quantitative imaging parameters that can be derived from textural feature analysis (as part of radiomics) are promising complements for improved characterization of tumor heterogeneity, thus, supporting clinically relevant implementations of personalized medicine concepts. Nevertheless, establishing new quantitative parameters for tumor characterization requires the use of standardized imaging objects to test the reliability of results prior to their implementation in patient studies. METHODS: In this review, we summarize existing reports on heterogeneous phantoms with a focus on simulating tumor heterogeneity. We discuss the techniques, materials, advantages, and limitations of the existing phantoms for PET, CT, and MR imaging modalities. CONCLUSIONS: Finally, we outline the future directions and requirements for the design of cross modality imaging phantoms.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Neoplasias/patologia , Impressão Tridimensional